1. Number of times of the repetition accuracy inspection 4P feeder: 30 times 2P feeder: 60 times (range of the monitor scale: 0.1mm) 2. After performing inspection of the repetition accuracy 1) If the pocket is located in the box while performing the repetition accuracy inspection as many times as designated, do not calibrate the […]
Category Archives: SMT Machines MRO
From Kit Manager or Kit Handy, it is possible to check the current condition of the devices on the machine. Follow the procedures below to check the devices on the machine. 8.6.1 Using Kit Manager 1. Open Kit Manger by using the shortcut in the start up menu. 2. Enter a user ID and then […]
If there is a vision error or pick up errors for a feeder, a device check is required for that position before production can be resumed. Follow the procedures below to perform a device check. 8.5.1 Using Kit Handy 1. Start the Fuji Information Terminal and tap the Windows mark to display the [Start Menu]. […]
The production program (Man-Machine Interface, MMI) is composed of the following data parts: PCB data: data related to PCB Placement data: data on the components to be placed on PCB including their positions (coordinates) Component data: data related to the components Feed data: data related to the feeder Vision data: data related to vision recognition […]
This can only be performed for feeders that are in the current job. This cannot be performed for feeders to be used in the next job or jobs not in the machine. To set up feeders for such jobs, use External Changeover. This creates a relationship between the feeder and the part, and checks to […]
Alarm Display: A.7A0 Alarm Name: Heat Sink Overheated 1. Situation at Alarm Occurrence: Occurred when the control power supply was turned ON. Cause: A SERVOPACK fault occurred. Corrective Actions: Replace the SERVOPACK. Cause: The overload alarm has been reset by turning OFF the power too many times. Corrective Actions: Change the method to reset the […]
Alarm Display: A.740 Alarm Name: Overload of Surge Current Limit Resistor 1. Situation at Alarm Occurrence: Occurred when the control power supply was turned ON. Cause: A SERVOPACK board fault occurred. Corrective Actions: A SERVOPACK fault occurred. 2. Situation at Alarm Occurrence: Occurred during operations other than the turning ON/OFF of the main circuit. Cause: […]
Embedded in the CP-45F/V and the CP-45FS is a high-speed CPU that provides the production and production management information of PCB, and is designated for creating and editing the production program as well. The system operation can reading be learned by using the MMI based on Windows 98. 1.5.1. PCB production Program selection The CP-45F/V […]
1.4.1. Power requirements Voltage Single phase AC 220V ± 10 % AC 100V / 110V / 120V / 200V / 220V/ 230V / 240V (shall be changed the terminal of the transformer) Power Consumption: 2.6 KVA (Maximum) Frequency: 50 / 60 Hz Figure 1-3. The solution for switching the power terminal connection of a transformer […]
1.3.1. Size And Weight Of The Equipment Length Including Cover: 1,660mm Excluding projection of Conveyor Unit: 1,502mm Width: 1,540mm Height Up to the upper surface of cover: 1,408mm Up to the upper surface of monitor: 1,760mm Up to the upper surface of tower lamp: 1,945mm Weight: 1,150 kg 1.3.2. Requirements For Air Pressure Pressure: 4.5 […]