1) Ambient Air Temperature: Accuracy assurance 23 +/-2 degrees centigrade Operation assurance 5 to 40 degrees centigrade
(The average over a period of 24 hours does not exceed 35 degrees C.)
2) Relative Humidity: 45 to 60%, no dewing
3) Atmosphere: Dust and corrosive gas free
4) Floor Condition: Flat and solid enough
The machine may present larger vibration, if the floor condition is not proper.
5) Power Requirements: 200V +/-10%, 3-phase, 50/60 Hz
208/220/240/380/400/415/440V using optional power transformer
NB) The power transformer is standard in export model.
Power consumption 1.5kW
Installed Capacity 4.0kVA
Leakage current 20mA or less
In case there are other machines, such as compressor, welding machine, wave-soldering machine with contacts, reflow oven, which may generate noise, do not use the power and ground common to those machines.
Take the power independently from the switchboard and take the ground independently.
Improper power and environmental condition will create serious problems on the machine, so the power and environmental requirements must be observed strictly. Contact us, if you have any questions.
As the acrylic safety cover is clear and transparent, the strong room light and the direct sunlight coming inside the machine may badly affect the vision processing. Contact us beforehand, if such a case is assumed.