Enter the body size and element information in part data. Vision type 140 uses the body center while vision type 145 uses the part center.
Due to the use of frontlighting, there are cases where the image of the ball grid may vary depending on the shape of the leads and the lighting conditions.
In such cases, it may be necessary to make adjustments to the ball grid position, length and width of the lead information in element information.
Inspection of certain parts may not be possible due to variations in the body color and the and the image of the ball grid.