Prepare Machine Prepare the machine for vacuum verification using the following procedure. 1. Remove all nozzles from the spindles using the Head/Changer Nozzle Setup window. Refer to the Installation/Removal of Nozzles section in the Nozzle Tip Assembly module. 2. Remove the safety cover below the hinged cover. 3. Open the hinged cover to access the […]
Category Archives: SMT Machines MRO
How to Verify Main Vacuum Pressure Verify the Pneumatic Panel assembly main pressure using the following procedure. This panel is located behind the rear, center fan panel. 1. Remove the Center Rear Cover Assembly of the machine by pulling on the handle. 2. Remove the 2 top screws from the rear panel containing the cooling […]
Replace or align a Coupler Body Assembly using the following procedure. 1. Park the FlexJet Head Assembly at a maintenance position. 2. Place the machine in the powered down mode. Then execute your site’s Lockout/Tagout procedure. 3. Open the hinged machine cover to access the FlexJet Head. Then remove the safety cover below the hinged […]
Remove a FlexJet Head using the following procedure. 1. Park the FlexJet Head Assembly at a maintenance position. 2. Place the machine in the powered down mode. Then execute your site’s Lockout/Tagout procedure. 3. Open the hinged machine cover to access the FlexJet Head. Then remove the safety cover below the hinged cover. 4. Remove […]
Install a FlexJet Head using the following procedure. 1. Move the beam(s) to a maintenance position using Manual Control. 2. Place the machine in the powered down mode. Then execute your site’s Lockout/Tagout procedure. 3. Use ESD precautionary measures and configure the Head Control Asm PC BD according to the Maintenance Support Document, PC Jumper […]
Alarm Display: A.02b Alarm Name: System Parameter Checksum Error 2 Situation at Alarm Occurrence: Occurred when the control power supply was turned ON. 1. Cause: The control power supply lowered and sometimes ranged from 30 VAC to 60 VAC. 1. Corrective Actions: Correct the power supply, and set Fn005 to initialize the parameter. 2. Cause: […]
Alarm Display: A.02A Alarm Name: Parameter Checksum Error 2 Situation at Alarm Occurrence: Occurred when the control power supply was turned ON. 1. Cause: The control power supply lowered and sometimes ranged from 30 VAC to 60 VAC. 1. Corrective Actions: Correct the power supply, and set Fn005 to initialize the parameter. 2. Cause: The […]
Category: A 1. Extended Support for Various PCB Thicknesses: Support for PCBs thinner than 0.5 mm (0.3 mm minimum) is available and Support for PCBs thicker than 5.0 mm (3.0 mm minimum, 6.0 mm maximum) is also available. 2. Automatic Conveyor Width Change (under development): A motor is used to change the conveyor width based […]
Acceleration control (XY-table): In 5 levels are UHi, Hi, Mid, Low, ULow. Controllable axes: A total of 12 axes are Cam, X, Y, Z, D1, D2, Pθ, Fθ, Rθ, NC, NZ and NY. CPU: Intel Pentium type. Maximum number of input sequences: 5000 sequences/PCB (this is the total number of sequences for both PCBs. Program […]
Notes: a. If incorrect orientation is detected, a vision error is issued and the part is rejected. This function can be used on the condition that bump arrangements are not perfectly symmetric, all bumps are registered in the part settings, and the bump detection rate is set to 100%. b. Detection of missing bumps does […]