This is used for checking the panel stopping position when the panel stopping position function is being used on the NXT. It is necessary to have a compatible version of Fuji Flexa and NXT control software V3.10 or higher in order to use this function and the panel stopping position correction function must be enabled […]
Category Archives: SMT Machines MRO
Header J22 determines the source for onboard static RAM backup power on the MVME162P4. In the factory configuration, VMEbus +5V standby voltage serves as primary and secondary power source (the onboard battery is disconnected). The backup power configurations available for onboard SRAM through header J22 are illustrated in the following diagram. Note: For MVME162P4s without […]
Some IP bus implementations make use of the Strobe? signal (pin AA19 on the Petra ASIC) as an input to the IP modules from the Petra IP2 sector. Other IP interfaces require that the strobe be disconnected. With a jumper installed between J19 pins 1-2, a programmable frequency source is connected to the Strobe? signal […]
This is used with the optional automatic backup pin function on the NXT. It is necessary to have Fuji Flexa V1.5.4 or higher and NXT control software V3.10 or higher in order to use this function. In addition, if the NXT does not have this option, then any settings made regarding this are ignored by […]
Error Code:124 Error Text: Operational failed because GEM is not operational. Description: The requested operation could not be performed because GEM is not operational. Cause: GEM is not installed or there is no communication with GEM. Solution: Ensure that GEM is installed and that communication is up and try again. Error Code:125 Error Text: Requested […]
#201. P/N: 630 137 4949 | Base #203. P/N: 630 126 6091 | Assy Gear(Makitori) #203-01. P/N: 630 126 6022 | Gear(Makitori) 1 #203-02. P/N: 630 126 6039 | Gear(Hira-3) 1 #203-03. P/N: 630 007 1771 | Bearing Radial #204. P/N: 630 160 2721 | Assy Gear(Hasuba) #205. P/N: 630 157 1911 | Assy Gear(Hira-1) […]
Error Code:121 Error Text: Unable to execute the order related command. Cause: – A similar command is currently being executed. Solution: Wait till the current command is executed and then try again. Error Code:122 Error Text: Order on machine already exists,use a different name. Description: The name entered for the order to be created for […]
By setting which feeders are available for the NXT machine, an unavailable feeder will not be selected when optimization is performed. 1. Select the [Top] or [Bottom] tab from the job information bar depending on the side of the panel the machine to be edited is located. 2. Double-click the name of the line to […]
Alarm Display: A.040 Alarm Name: Parameter Setting Error 1 Situation at Alarm Occurrence: Occurred when the control power supply was turned ON. Cause: Parameter is set out of range. Corrective Actions: Set the parameter within the specified range. Cause: The SERVOPACK EEPROM and the related circuit are faulty. Corrective Actions: Replace the SERVOPACK.
By setting which nozzles are available for the NXT machine, only the nozzles specified as being available display when a user is selecting a nozzle for a position. This ensures that a nozzle is not accidentally selected that is not available and reduces the amount of choices in the nozzles drop-down list, thus allowing easier […]