The X-Series placement machines are available in four different variants: SIPLACE X2 S-A, B or C SIPLACE X3 S-A, B, C or D SIPLACE X4 S-A, B, C, D or E SIPLACE X4i S-A, B, C, D or E Nozzle changers increase the flexibility of the placement heads when it comes to processing different components. […]
Category Archives: SMT Machines MRO
If no outside data files are available, it is possible to create a job completely through data entry. Follow the roadmap below to create a basic job through manual data entry. Generating recipes is not necessary for the NXT unless one wants to view reports. 1. Create a job manually. 2. Add a line to […]
1. Preparations (1) Rotate the guide clockwise until it will turn no further and then turn it counter-clockwise by one revolution. (2) Raise the spindle by rotating it counter-clockwise. Then raise and rotate the stopper ring clockwise to check that the spindle has been raised sufficiently. (3) Rotate the stopper counter-clockwise to lower it so […]
Camera Center XC/YC (Temporary Measurement) 1. Mount a 10 mm nozzle in the holder. CCD Camera: Back Light Nozzle Line Scan: Front Light Nozzle 2. Execute the following command sequence to perform the automatic measurement: [SET] – [PROPER] – [CAMERA] – [CAMERA POS] – [Partscam.#] – START and run the nozzle center check at least […]
Functional Description The 8mm High Performance DL-60 (Gold Plus) feeder advances components from dual Reel Holders to the Peel Edge on the Window where the ylar (cover) tape is removed. The components are then advanced to the feeder pickup position where they wait for pickup by the machine. Procedures and Adjustments The subsections that follow […]
This part describes the basic SMT In-Line work process and the method to change the work from the existing work to the new one during operation. 1. Screen Printer: Machine Stop → Metal Mask Removal/ Washing → Backup Pin Removal → New Work File Loading → Backup-Pin Rearrangement → Conveyor Width Adjustment → Metal Mask […]
Suggestion: Check every 140 hours (once a week). This part describes changing the nozzle holder set on the transfer head, the nozzles and the vacuum filter, and also describes cleaning and lubricating the optional nozzle changer and the nozzles set on it. Flow chart: 1. Selecting the operation table 2. Removal a. Removing the nozzle […]
1) Number of Placement Heads: 4 heads (30mm pitch) 2) Z-axis Drive: 4 AC servomotors, Resolution 0.006mm 3) Rotation Axis Drive: 2 AC servomotors, Resolution 0.022 degree 4) Pickup Error Detection: Negative pressure check or vision recognition 5) Component Alignment Method: Vision alignment 6) Pickup Method: Suction by vacuum 7) Placement Accuracy: CHIP: +/- 0.06mm […]
1. 240 x 128 pixel LCD display, black and white, backlit: The menus appear on the LCD display and the recorded position deviation signals are displayed graphically. All the relevant parameters, such as time base, measured times, amplitude scaling, signal level and cursor positions with the associated time differences appear as alphanumeric information over the […]
Overview 1. Pickup position 2. Motors for moving components 3. Motor for cover foil 4. Display, operating panel and status display 5. Mechanical and electrical unlocking function The X feeders enables you to set up a separate feeder for each component used at the machines (single track feeders). This ensures optimum use of the machine […]