Category Archives: SMT Machines MRO

Servo Motor Error Code No. 24 on Samsung Techwin SM321 SMT Equipment

Alarm Contents: Positioning error limit alarm. Operating Condition: After control power is turned on. Causes: Servo-Amp. damaged. Measures:Servo-Amp change. Causes: While the motor is running Servo-motor starting failure in response to the input pulse. Extremely small limit of positioning error. Measures: Servo tuning adjustment (Pr.5E increase). Motor cable check. Servo-Amp change. Servo-motor change.

Servo Motor Alarm Code No. 23 on Samsung Techwin SM321 SMT Machine

Alarm Contents: Motor encoder communication data trouble alarm. Operating Condition: After control power is turned on While the motor is running. Causes: Communication error due to the noise. Measures: Check the power input to the encoder. (+5V ± 5%) Check the FG wiring. Causes: Motor encoder cable connection error or failure. Measures:Motor encoder cable check […]

Servo Motor Alarm Code No. 18 on Samsung SM321 SMT Machine

Alarm Contents: Regenerationover load alarm. 1. Operating Condition: When the motor is running (when stopped). Causes: Over-charging of the Servo-Amp. internal owing to the overload. Measures: Reduce the load. Modify the operation pattern. 2. Operating Condition: While motor is running (during operation). Causes: Over-charging of the Servo-Amp. internal owing to the high speed operation. Measures: […]

Servo Motor Alarm Code No. 16 on Samsung SM321 SMT Machine

Alarm Contents: Servo-Amp. overload alarm. Operating Condition: After the main power is turned on When the motor is running. Causes: Overload larger than rated load. Measures: Increase the capacity of servo-motor and Amp. Causes: Servo-motor vibration. Measures: Servo tuning adjustment. Causes: Wrong connection or shortage of the motor cable. Measures: Check and rectify the motor […]

Servo Motor Alarm Code No. 15 on Samsung SM321 SMT Machine

Alarm Contents: Servo-Amp. over-heat alarm. Operating Condition: After the main power is turned on When the motor is running. Causes: Overheating of Servo-Amp above the rated temperature. Measures: Check the surrounding machine and cooling fan of Servo-Amp. Causes: Overloading on the Servo-Amp. Measures: Increase the capacity of Servo-motor and Amp. Decrease the load.