Alarm Contents: Servo-Amp. Over current alarm Operating Condition: After the main power is turned on when the motor starts. Causes: Servo-Amp. damaged Motor UVW cable broken Motor UVW cable short Servo-motor damaged Measures: Servo-Amp.change Motor cable change Motor cable Servo-motor change
Category Archives: SMT Machines MRO
Position: Y Frame Bracket Maker: Hirose Pin: DF1B-2428SCF Connector: DF1B-6ES-2.5RC Working Tool: DF1B-TA2428SHC Others: The tool exclusively used for the cable connection must be used. Position: X Motor Maker: AMP Connector: 172160-1 Pin: 170361-1 Working Tool: HTR 2445A 11-01-0026 Others: The tool exclusively used for the cable connection must be used.
Alarm Contents: Servo-Amp. main power Low voltage alarm 1. Operating Condition: After supplying the control power. Causes: Servo-Amp. damaged Measures: Servo-Amp. change 2. Operating Condition: After the main power is turned on Causes: Voltage drop of the main power When using a single phase power, check the input wiring of L1 – L3 Servo-Amp. damaged […]
Alarm Contents: Servo-Amp control power. High voltage alarm. 1. Operating Condition: After supplying the control power Causes: X,Y Servo-Amp. regenerating resistor damage, disconnection Servo-Amp. damaged Measures: Resistor reconnection Resistor change Servo-Amp. change 2. Operating Condition: During motor running Causes: X,Y Servo-Amp.regenerating resistor damage, disconnection Servo-Amp. damaged Measures: Resistor reconnection Resistor change Servo-Amp. change
When an error occurs, the 7 segment LEDs of the motor drive will flicker. As well, the corresponding alarm code is generated. It is of “Err **” form and the “**” will express the corresponding alarm code. In this case, take measures against the corresponding alarm code referring to the information shows M.R.O chapter.
Alarm Contents: Servo-amp. Control power, low voltage alarm Servo Motor Alarm Code No.: 11 Alarm Contents: Servo-amp. Control power, low voltage alarm 1. Operating Condition: After supplying the control power. Causes: Low voltage of the control power at the r – t terminal. Servo-Amp. damaged. Measures: Measure the control power input voltage through the r […]
HIOBA: CN2 CAP: HEAD ILLUMINATION BOARD CN2 HIOBA: CN3 CAP: FLAT CABLE(HD CAN) HIOBA: CN4 CAP: HEAD ILLUMINATION CN1 HIOBA: CN5 CAP: SIDE ILLUMINATION UP/DN SOL HIOBA: CN6 CAP: R AUX SENSOR HIOBA: CN7 CAP: SIDE ILLUMINATION U/D SENSOR HIOBA: CN8 CAP: Z1~Z6 HOME SENSOR HIOBA: CN9 CAP: R HOME SENSOR HIOBA: CN10 CAP: SWING […]
HIBA: CN1 CAP: HEAD INPUT / OUTPUT BOARD CN4 HIBA: CN2 CAP: HEAD INPUT / OUTPUT BOARD CN2 HIBA: CN3 CAP: FLY OUTER LED BOARD HIBA: CN4 CAP: FID OUTTER BOARD HIBA: CN5 CAP: FID INNER BOARD HIBA: CN6 CAP: HEAD SIDE ILLUMINATION *HIBA = Head Illumination Board Assembly *CAP = Counterpart Assembly Point
The flat cable configuration ranges from the head bracket to the Y frame bracket and it is composed of a total of 20 round cables. #1. Name: X Axis Motor Encoder Cable Defect Symptom: Abnormal X motor movement #2. Name: X Axis Motor Power Cable Defect Symptom: X motor unable to move #3. Name: X […]
#1. Shutter Speed/Mode Setting(DIP Switch) #1.1 Switch 1-4 : Shutter speed | Switch-Setting: OFF #1.2 Switch 5 : FRAME/FIELD | Switch-Setting: FRAME #1.3 Switch 6-8 : External trigger shutter mode, restart/reset mode | Switch-Setting: Normal #1.4 Switch 9 : Gamma ON/OFF | Switch-Setting: OFF #1.5 Switch 0 : GAIN | Switch-Setting: Manual #2. Manual GAIN […]