Alarm Contents: Servo-Amp. main power Low voltage alarm
1. Operating Condition: After supplying the control power.
Causes:
Servo-Amp. damaged
Measures:
Servo-Amp. change
2. Operating Condition: After the main power is turned on
Causes:
Voltage drop of the main power
When using a single phase power, check the input wiring of L1 – L3
Servo-Amp. damaged
Measures:
Check the main power input Main power connection
Servo-Amp. change
3. Operating Condition: When the motor is running
Causes:
Servo-Amp. damaged
Voltage drop of the main power
Measures:
Servo-Amp. Change Check the input points of main power such as relay, etc.