The flat cable configuration ranges from the head bracket to the Y frame bracket and it is composed of a total of 20 round cables.
#1. Name: X Axis Motor Encoder Cable
Defect Symptom: Abnormal X motor movement
#2. Name: X Axis Motor Power Cable
Defect Symptom: X motor unable to move
#3. Name: X Axis Sensor Cable
Defect Symptom: X axis home sensor and limit sensor unable to work
#4. Name: Fiducial Camera Data Cable
Defect Symptom: Defective fiducial camera image and recognition
#5. Name: Fly Camera #1,2,3 Cable
Defect Symptom: Defective image of the fly cameras #1~#3
Remarks: Use Spare
#6. Name: Fly Camera #4,5,6 Cable
Defect Symptom: Defective image of the fly camera #4~#6
Remarks: Use Spare
#7. Name: Fly Camera Power Cable
Defect Symptom: Entire fly camera image not displayed
#8. Name: Z1, Z2 Encoder Cable
Defect Symptom: Z1 and Z2 abnormal and motor alarm
#9. Name: Z1, Z2 Power Cable
Defect Symptom: Z1 and Z2 work abnormally or unable to work
#10. Name: Z3, Z4 Encoder Cable
Defect Symptom: Z3 and Z4 abnormal and motor alarm
#11. Name: Z3, Z4 Power Cable
Defect Symptom: Z3 and Z4 work abnormally or unable to work
#12. Name: Z5, Z6 Encoder Cable
Defect Symptom: Z5 and Z6 abnormal and motor alarm
#13. Name: Z5, Z6 Power Cable
Defect Symptom: Z5 and Z6 work abnormally or unable to work
#14. Name: Mirror Swing Motor Encoder Cable
Defect Symptom: Abnormal fly mirror movement and motor alarm
#15. Name: Mirror Swing Motor PWR Cable
Defect Symptom: Fly mirror unable to move
#16. Name: R Axis Step Motor Power Cable
Defect Symptom: R axis moves abnormally or unable to move
#17. Name: R Axis Step Motor Power Cable
Defect Symptom: R axis moves abnormally or unable to move
#18. Name: Head Sensor + 24V Power Cable
Defect Symptom: Z, R and SW axes home sensor works abnormally. Problem with power supply to the head
#19. Name: Head IO B’D CAN Signal Cable
Defect Symptom: Problem with MPU STOP I/O #5 during operation
#20. Name: Head Vacuum/Blow Sol. Cable
Defect Symptom: Solenoid works abnormally or unable to work