#1 Mark: YH / Y1H | Definition: Y HOME | LED State (Detected by Sensor): On | LED State (Not Detected by Sensor): Off #2 Mark: YP / Y1P | Definition: Y +LIMIT | LED State (Detected by Sensor): Off | LED State (Not Detected by Sensor): On #3 Mark: YM / Y1M | Definition: […]
Category Archives: SMT Machines MRO
Possible Cause: Defective motor driver Measures: Replace it. Remarks: Motor and dirver.
Possible Cause 1. Differentar pameter(s) of motor. Measures: Reload the standard parameter(s). 2. Defective motor driver Measures: Replace it. Remarks for 1 & 2: Drive and Motor. 3. Defective ball screw Measures: Replace it.
Possible Cause: 1. Defective home sensor position/movement Measures 1) Check the position and movement of the sensor 2) Axis Sensor Board (Check J9060162A) – CN1 : Y1 Home / Y1 + Limit /Y1-Limit – CN3 : X Home / X +Limit / X -Limit Remarks: Rack Assembly, Cableway. 2. Defective coupling connection Measures: Check the […]
Possible Cause: 1. Defective home sensor position/ movement Measures: 1) Check for sensor movement and position. 2) Axis Sensor Board (Check J9060162A ) – CN1 : Y1 Home / Y1 + Limit /Y1-Limit – CN3 : X Home / X +Limit / X -Limit Remarks: Rack assembly Cableway 2. Defective coupling connection Check the state […]
1. Replace the motor in the same manner by referring to: (1) Manipulate the teaching box to move the X-Frame to the rear side. (2) Shutdown off the main switch on the front side of the machine. (3) Remove the cable of the corresponding motor. (4) Unscrew the fixing screws (M4- 4 sets) to remove […]
1. Replace the motor in the same manner by referring to: (1) Manipulate the teaching box to move the X-Frame to the rear side. (2) Shutdown off the main switch on the front side of the machine. (3) Remove the cable of the corresponding motor. (4) Unscrew the fixing screws (M4- 4 sets) to remove […]
Tension (N): 25 N Frequency (Hz): 450 ± 10% Remarks: Use the U-505(Tension Gage)
Tension (N): 25 N Frequency (Hz): 337.5 ± 10% Remarks: Use the U-505(Tension Gage)
Tension (N): 17 N (13.5N ~ 20.5N) Frequency (Hz): 177 ± 10% Remarks: Use the U-505(Tension Gage)