* Tools: Screw Driver * Parts: SERVO MOTOR [P20B10150HXS2C] (J3108015A) * This is example of motor(G1F-Y11) replacement. 1) Remove the back up pin and PCB, turn the power Off, and then replace the G1F-Y11 Motor. 2) As pressing the Emergency, turn the power On. 3) If Kimchi runs and you are asked to Home, select […]
Category Archives: SMT Machines MRO
Tools: Screw Driver Parts: SERVO MOTOR-X [P30B08075DXS48] (J3108023A) 1. Remove the back up pin and PCB, turn the power Off, and then replace the G1F-X Motor. 2. Release the Emergency, and turn the power On. 3. Kimchi runs, and Home position comes out Failure or Success. It is a general phenomenon of assembling procedure, so […]
This section expounds considerations while LEDs are placed on the circuit patterns after the solder paste printing. The LED placement requires the optimal shape/settings of a pick-and-place nozzle. 1. Shape of Pick-and-Place Nozzle Nichia determines the optimal shape of a pick-and-place nozzle for each model through experiments. They recommend the optimal nozzle shape and size […]
After the Shuttle Tray Feeder has been installed, register it from the “Tray Feeder Setting” dialog box (Sys. SetupÆTray) in Figure C-1 as follows. 1 Enter the Tray Feeder name to specify in the Name item. 2 Select ‘FW-20CS (Shuttle) (393221)’ from the Type item. 3 Enter the origin of Tray Feeder using the method […]
The mechanical check software (servo adjustment software) is used to perform CP643E’s servo adjustment. The servo adjustment procedure using mechanical check software is described below. This procedure below applies only to Servo ROM305 or newer versions. 1) Start the mechanical check software by entering the following: [3] (axis selector SW) + [RESET] + [POWER ON]; […]
X-Y Positioning System The X-Y positioning system locates the printed circuit board under the insertion tooling and is equipped with a rotary indexing table that indexes in 90° increments, from 0° to 360° in a clockwise rotation. This rotary table is air motor driven under pattern program control and requires less than one second to […]
The memory of the intermediate distributor can contain incorrect values for the maximum and minimum travel paths of the Z axis Machie Model: Siemens ASM Siplace X2 X3 X4 1. Error/problem After a C&P 20 placement head has been replaced, the values for zero point correction and the maximum and minimum position for the Z […]
Error Text: Invalid serial number range Description: The serial numbers must be correctly formatted and the ranges are not allowed to overlap. Solution: Check out the serial numbers again and again and make sure the serial numbers is totally correct.
Module: X-Y Axis Part Error Code: $0100 Cause: Invalid nozzle length Invalid nozzle length value among Nozzle data.(0 value is inputted.) Solution: Check Nozzle Data with command of in MMI and the input the correct data.
UIC Universal 8 mm High Performance DL-60 Gold Plus 7 inch Dual Lane Spliceable Tape Feeder Part Number 49889212 Offset Setting Mode 1. Make sure the feeder is latched and powered up. 2. Press and release the lane select button to select the lane to be adjusted. 3. Press and hold the lane select button […]