Having issues with X/Y Homing Was Not Performed Of X-Axis Frame on Samsung Techwin SM321 SMT Component Assembly Machine? Read our step-by-step SMT maintenance solution below. If you require replacement feeders, nozzles, or sensors, contact SMTBOX for OEM-compatible parts.

Possible Cause:
1. Defective home sensor position/ movement
Measures:
1) Check for sensor movement and position.
2) Axis Sensor Board (Check J9060162A )
– CN1 : Y1 Home / Y1 + Limit /Y1-Limit
– CN3 : X Home / X +Limit / X -Limit
Remarks: Rack assembly Cableway
2. Defective coupling connection Check the state of the coupling connection.
Measures: Check the state of the coupling connection.
3. Defective motor and motor driver
Measures: Check and replace the motor driver. (Check after replacement with other motor (driver).
Remarks: Motor and driver.

Our editorial team consists of senior SREs, mechanical engineers, and SMT assembly specialists with over 15 years of industry experience in PCB assembly line optimization. All technical articles are reviewed and verified for mechanical and electronic compatibility before publication.