1) Parts Feeders F1-82-0603 8mm tape, 2mm index, for 0603 (0201) F1-82-1005 8mm tape, 2mm index, for 1005 (0402) F1-84 8mm tape, 4mm index F1-12 12mm tape F1-16 16mm plastic tape F1-24 24mm plastic tape F1-32 32mm plastic tape PS-32A 32mm adhesive paper tape F1-44 44mm plastic tape F1-56 56mm plastic tape F2-82-0603 Intelligent Feeder, […]
Category Archives: SMT Machines MRO
Power Supply: Only the secondary side is factory-prepared. The power cable (VCT 4×3.5mm2 or equivalent) to the terminal block of the machine is to be prepared by customers. Air Supply: The air hose with a female coupler is to be prepared by customers. Machine side coupler Hicoupler 20PM of Nitto Koki (factory-installed) Hose side coupler […]
1) Alarm Devices: Buzzer and Signal Tower 2) 100V Outlet (for the tape cutter) Front Station (1A) 1 outlet Rear Station (1A) 1 outlet 3) USB Port (Ver. 1.00, 12Mbbs, 1 each on front and rear) To be used for a barcode reader for Intelligent Feeder System and a USB memory for data backup Not […]
1) Ambient Air Temperature: Accuracy assurance 23 +/-2 degrees centigrade Operation assurance 5 to 40 degrees centigrade (The average over a period of 24 hours does not exceed 35 degrees C.) 2) Relative Humidity: 45 to 60%, no dewing 3) Atmosphere: Dust and corrosive gas free 4) Floor Condition: Flat and solid enough The machine […]
(1) Axis Control: X/Y/Z/R/S axes, Semi-closed loop control with AC servomotors (2) Position Control: Absolute method (3) Data Input Increment: X/Y/Z/S 0.01 mm or 0.1 mil Rotation 0.01 degree (4) Data Input Method: Manual, teaching, offline programming (5) Memory Capacity: Max. 3000 steps per program, Max. 500 programs in the built-in hard disk (6) External […]
4.4 Parts Feeder 1) Number of Component Types: Max. 120 types, using 8mm tape feeders Front station: 60 types Rear station: 60 types With the optional MXR-20 installed: 60 front + 22 rear + 20 (MXR-20) = Max. 102 types With the optional MX-20D installed: 60 front + 18 rear + 40 (MX-20D) = Max. […]
Use this vision type when part recognition is not possible using any other vision type. In the shape data, set the vision type to 170, specify a setting for [Lead Brightness] and specify the check area and select either 1 or 2 for the p_pattern in the element information. Based on this data, if it […]
Enter the body size and element information for leads or projections. Vision type 160 uses the body center while vision type 165 uses the part center. Element inspection is not performed if the [Result] option for that element is set to “Don’t inspect”. The body inspection points are automatically determined based on the data for […]
Enter the body size and element information in part data. It is necessary to create separate element information for leads of different width and length. Vision type 153 uses the body center while vision type 158 uses the part center. The outer form of the part is used to determine the rough positioning of the […]
Enter the body size and element information in part data. It is necessary to create separate element information for leads of different width and length. Vision type 152 uses the body center while vision type 157 uses the part center.