Enter the body size in part data. There is no need to enter element information. Be sure to include projections such as leads in the body size. The reference point for the part is the part center.
Category Archives: SMT Machines MRO
Enter the body size in part data. There is no need to enter element information. The reference point for the part is the part center.
Vision Type 61 Tantalum Spragues Vision Type 63 Tantalum Spragues (polarity check performed) Enter the body size in part data. There is no need to enter element information. The projection of the tantalum sprague must be included in the body size. The reference point for the part is the part center. To perform a polarity […]
Alarm Display: A. 410 Alarm Name: Undervoltage 1. Situation at Alarm Occurrence: Occurred when the control power supply was turned ON. Cause: A SERVOPACK board fault occurred. Corrective Actions: Replace the SERVOPACK. 2. Situation at Alarm Occurrence: Occurred when the main circuit power supply was turned ON. Cause: The AC power supply voltage is 120 […]
Enter the body size in part data. There is no need to enter element information. The reference point for the part is the part center.
This section provides a list of the vision types for the NXT and an explanation of the processing method used for each type. It is possible to use older vision types for other Fuji machines in some cases. When making part data, if the parts are to be shared between the NXT and other Fuji […]
The part reference point is defined as the point on the part that is aligned with the placing coordinates on the panel when the part is placed. Body center The center is taken from the outer-most points of the body; top, bottom, left, and right. Part center The part center is defined as follows. Part […]
Alarm Display: A. 400 Alarm Name: Overvoltage 1. Situation at Alarm Occurrence: Occurred when the control power supply was turned ON. Cause: A SERVOPACK board fault occurred. Corrective Actions: Replace the SERVOPACK. 2. Situation at Alarm Occurrence: Occurred when the main circuit power supply was turned ON. Cause: The AC power voltage is 290 V […]
Alarm Display: A. 330 Alarm Name: Main Circuit Wiring Error 1. Situation at Alarm Occurrence: Occurred when the control power supply was turned ON. Cause: A SERVOPACK board fault occurred. Corrective Actions: Replace the SERVOPACK. 2. Situation at Alarm Occurrence: Occurred when the main circuit power supply was turned ON. Cause: In the DC power […]
Alarm Display: A. 320. Alarm Name: Regenerative Overload. 1. Situation at Alarm Occurrence: Occurred when the control power supply was turned ON. Cause: A SERVOPACK board fault occurred. Corrective Actions: Replace the SERVOPACK. 2. Situation at Alarm Occurrence: Occurred when the main circuit power supply was turned ON. Cause: The power supply voltage is 270 […]