Alarm Display: A.d10 Alarm Name: Motor-Load Position Error Pulse Overflow Situation at Alarm Occurrence: Occurred when servo was ON or during operation. Cause: Motor rotation direction and scale installation direction is opposite. Corrective Actions: Install the scale in the opposite direction, or reverse the setting of fully-closed encoder usage method (Pn002.3). Cause: Position of the… Continue reading about Alarm Display: A.d10. Alarm Name: Motor-Load Position Error Pulse Overflow on Sony SI-F209 Electronic Part Mounter
Category Archives: SMT Machines MRO
Alarm Display: A.d02 Alarm Name: Position Error Pulse Overflow Alarm by Speed Limit at Servo ON. Situation at Alarm Occurrence: Occurred when the servomotor was running. Cause: The servo turned ON with accumulated errors, and reference pulse was input during operation at the speed limit, therefore, the errors exceeded the Position Error Pulse Overflow Alarm… Continue reading about Alarm Display: A.d02 Alarm Name: Position Error Pulse Overflow Alarm by Speed Limit at Servo ON of Sony SI-F209 Electronic Part Mounter
Alarm Display: A.d01 Alarm Name: Position Error Pulse Overflow Alarm at Servo ON. Situation at Alarm Occurrence: Occurred when the control power supply was turned ON. Cause: Excessive position errors accumulated while the servo is OFF Corrective Actions: Do not run the servomotor in servo OFF status. Cause: With the setting not to clear the… Continue reading about Alarm Display: A.d01 Alarm Name: Position Error Pulse Overflow Alarm at Servo ON on Sony SI-F209 Electronic Part Mounter
Alarm Display: A.d00 Alarm Name: Position Error Pulse Overflow Situation at Alarm Occurrence: Occurred when the control power supply was turned ON. Cause: A SERVOPACK board fault occurred. Corrective Actions: Replace the Servopack. Situation at Alarm Occurrence: Occurred at the servomotor high-speed operation. Cause: The contact in the servomotor U, V, and W wirings is… Continue reading about Alarm Display: A.d00 Alarm Name: Position Error Pulse Overflow on Sony SI-F209 Electronic Part Mounter
#1. P/N: EP02-001924B | Part name: Harness Touch PANEL2 VGA Cable | Qty: 1 #2. P/N: EP02-001925A | Part name: Harness Touch PANEL2 Power Cable | Qty: 1
The menu structure and the functions of each command of MMI(Man-Machine Interface), which serves as the application program for the operation of this machine, are briefly explained in this chapter. For detailed information on each menu, please refer to “Chapter 11. PCB Edit Menu” ~ “Chapter 12. Production Menu”. 2.1. Man-Machine Interface (MMI) 2.1.1. Menu… Continue reading about Structure of MMI Menu For Samsung Component Placer CP45NEO Series
A alternate feeder An empty slot on a feeder table can be readied with the same part that is being supplied from another feeder position. When the original feeder runs out of parts, the pick-up position changes to this alternate feeder. Multiple alternate feeders can be specified. When an alternate feeder runs out of parts… Continue reading about Glossary of Fuji Scalable Placement Platform NXT Programming
Fujitrax Verfier issues parts out warnings for the tray unit-L based upon the user specified settings. When a parts out warning occurs for a tray, the operator has time to get a new tray, set it in a replacement drawer, verify it, and set it in the parts supply drawer. Once the drawer with the… Continue reading about 8.7.4 Replacing Trays With Non-Stop Tray Resupply (from NXT V3.10) for 8.7 Resupplying Parts During Production of 8. Fujitrax Verifier on FUJI NXT
Alarm Display: A.CF2 Alarm Name: Fully-closed Serial Converter Unit Communications Error (Timer Stopped) Situation at Alarm Occurrence: Occurred when the control power supply was turned ON or during operation. Cause: Noise interferes with the cable between serial converter unit and SERVOPACK. Corrective Actions: Correct the wiring around serial converter unit, e.g., separating signal line from… Continue reading about Alarm Display: A.CF2 Alarm Name: Fully-closed Serial Converter Unit Communications Error (Timer Stopped) on Sony SI-F209 Electronic Part Mounter
Alarm Display: A.CF1 Alarm Name: Fully-closed Serial Converter Unit Communications Error (Reception Error) Situation at Alarm Occurrence: Occurred when the control power supply was turned ON or during operation. Cause: Wiring of cable between serial converter unit and SERVOPACK is incorrect or faulty contact. Corrective Actions: Correct the cable wiring. Cause: The specified cable is… Continue reading about Alarm code: A.CF1. Alarm Name: Fully-closed Serial Converter Unit Communications Error (Reception Error) on Sony SI-F209 Electronic Part Mounter