Alarm code: A.CF1. Alarm Name: Fully-closed Serial Converter Unit Communications Error (Reception Error) on Sony SI-F209 Electronic Part Mounter

Sony Si F209 Compact Sized Fine Pitch Electronic Part Mounter

Alarm Display: A.CF1

Alarm Name: Fully-closed Serial Converter Unit Communications Error (Reception Error)

Situation at Alarm Occurrence: Occurred when the control power supply was turned ON or during operation.

Cause: Wiring of cable between serial converter unit and SERVOPACK is incorrect or faulty contact.
Corrective Actions: Correct the cable wiring.

Cause: The specified cable is not used between serial converter unit and SERVOPACK.
Corrective Actions: Use the specified cable.

Cause: Cable between serial converter unit and SERVOPACK is too long.
Corrective Actions: Use 20-m cable max.

Cause: Sheath of cable between serial converter unit and SERVOPACK is broken.
Corrective Actions: Replace the cable.