Defined Fault On Module: Conveyor Part of Samsung CP40 Pick And Place Machine

Samsung CP30CP40 CP45 CP45F CP45FV CP45NEO SMD SMT Pick Up Nozzle TN030

1. Action: Check that air pressure drops down below the standard values.

Error code: $2001 | Symptom and cause: Can’t move up the back up table (BUT). Backup table(BUT) fails to move up.

Error code: $2002 | Symptom and cause: Can’t move down the back up table (BUT). Backup table(BUT) fails to move down.

Error code: $2101 | Symptom and cause: Can’t clamp the rear edge fixer. Rear edge fixer fails to operate.

Error code: $2102 | Symptom and cause: Can’t release the rear edge fixer. Rear edge fixer fails to operate.

Error code: $2201 | Symptom and cause: Can’t clamp the hole fixer. Hole fixer fails to operate.

Error code: $2202 | Symptom and cause: Can’t release the hole fixer. Hole fixer fails to operate.

Error code: $2301 | Symptom and cause: Can’t clamp the side edge fixer. Side edge fixer fails to operate.

Error code: $2302 | Symptom and cause: Can’t release the side edge fixer. Side edge fixer fails to operate.

2. Action: This has no effect on operation or performance of a system.

Error code: $3001 | Symptom and cause: PCB exists on the input position Occurs when PCB exists on the input position.

Error code: $3002 | Symptom and cause: PCB exists on the wait position Occurs when PCB exists on the Wait position.

Error code: $3003 | Symptom and cause: PCB exists on the place position Occurs when PCB exists on the Place position.

Error code: $3004 | Symptom and cause: PCB exists on the output position Occurs when PCB exists on the Exit position.

3. Action: Remove PCB concerned.

Error code: $3010 | Symptom and cause: PCB exists on the input & wait position. Occurs when PCB exists on the Input and Wait position.

Error code: $3021 | Symptom and cause: Remove the PCB existing on the input & wait buffer. Occurs when PCB exists on the Input and Wait position.

Error code: $3022 | Symptom and cause: Remove the PCB existing on the place buffer. Occurs when PCB exists on the Place position.

Error code: $3023 | Symptom and cause: Remove the PCB existing on the output buffer. Occurs when PCB exists on the Place position.

4. Action: Check conveyor motor for proper operation.

Error code: $3101 | Symptom and cause: PCB isn’t reached to the wait area. PCB fails to reach to Wait position within limited time in conveyor.

Error code: $3102 | Symptom and cause: PCB isn’t reached to the place area. PCB fails to reach to Place position within limited time in conveyor.

Error code: $3103 | Symptom and cause: PCB isn’t reached to the output area. PCB fails to reach to Out position within limited time in conveyor.

Error code: $3201 | Symptom and cause: Can’t carry away PCB from the wait position. PCB fails to move away from the Wait position of conveyor.

Error code: $3202 | Symptom and cause: Can’t carry away PCB from the place position. PCB fails to move away from the Place position of conveyor.

Error code: $3203 | Symptom and cause: Can’t carry away PCB from the output position. PCB fails to move away from the Out position of conveyor.

5. Action: Check that air pressure drops down below the standard values.

Error code: $3302 | Symptom and cause: Can’t move down the wait stopper. Occurs when it fails to move up the wait stopper.

Error code: $3401 | Symptom and cause: Can’t move up the placement stopper. Occurs when it fails to move up the Placement stopper.

Error code: $3402 | Symptom and cause: Can’t move down the placement stopper. Occurs when it fails to move down Placement stopper.

Error code: $3501 | Symptom and cause: Can’t move up the exit stopper. Occurs when it fails to move up the Exit stopper.

Error code: $3502 | Symptom and cause: Can’t move down the exit stopper. Occurs when it fails to move down the Exit stopper.

6. Action: Reduce No. of Array PCB to 500EA or less.

Error code: $3600 | Symptom and cause: PCB is over in N PCB mode No. of Array. PCB prepared at PCB setup exceeds 500.

7. Action: Reduce No. of placement point to 3000 or less.

Error code: $3601 | Symptom and cause: PCB is over in Step Programming No. of placement point prepared at PCB setup exceeds 3000.

8. Action: Check for the link conditions of SMEMA cable and connector. Check the linked conditions between systems and proper.

Error code: $3700 | Symptom and cause: SMEMA input Time Over Error. SMEMA signal is not inputted within limited time.