Serial Connections on Motorola MVME162P4 VME Embedded Controller

EIA-232-D Connections to MVME712M (Sheet 1 of 6) of Serial Connections on Motorola MVME162P4 VME Embedded Controller

The MVME162P4 uses a Zilog Z85230 serial port controller to implement the two serial communications interfaces. Each interface supports:

1. CTS, DCD, RTS, and DTR control signals

2. TXD and RXD transmit/receive data signals

3. TXC and RXC synchronous clock signals

The Z85230 supports synchronous (SDLC/HDLC) and asynchronous protocols. The MVME162P4 hardware supports asynchronous serial baud rates of 110b/s to 38.4Kb/s.

EIA-232-D Connections to MVME712M (Sheet 2 of 6) of Serial Connections on Motorola MVME162P4 VME Embedded Controller

For additional information on the MVME162P4 serial communications interface, refer to the Z85230 Serial Communications Controller Product Brief listed under Manufacturer’s Documents in the Related Documentation appendix. For additional information on the EIA-232-D interface, refer to the EIA-232-D Standard.

EIA-232-D Connections to MVME712M (Sheet 3 of 6) of Serial Connections on Motorola MVME162P4 VME Embedded Controller

The following figures illustrate the signal relationships and signal connections in the various serial configurations available for ports A and B.

EIA-232-D Connections to MVME712M (Sheet 4 of 6) of Serial Connections on Motorola MVME162P4 VME Embedded Controller

EIA-232-D Connections to MVME712M (Sheet 5 of 6) of Serial Connections on Motorola MVME162P4 VME Embedded Controller

EIA-232-D Connections to MVME712M (Sheet 6 of 6) of Serial Connections on Motorola MVME162P4 VME Embedded Controller

EIA-530 Connections of Serial Connections on Motorola MVME162P4 VME Embedded Controller

EIA-485 And EIA-422 Connections of Serial Connections on Motorola MVME162P4 VME Embedded Controller
Note: Model Number: MVME162P-344SE, Characteristics: 32MHz 68040, 16MB SDRAM, 2 SIO, 4 DMA IP, SCSI/Ethernet is used on Universal UIC HSP4797L Hitachi Sanyo TCM-X100 P.C.B. Mount 6300901030