Error Code: 103
Error Text: Invalid changeover method Invalid changeover method.
Description: This is a software error. The function is not yet implemented.
Solution: Report error to your service representative.

Error Code: 104
Error Text: Invalid order start count
Description: The starting count must be al least1.
Solution: Change the starting count.

Error Code: 105
Error Text: Board in work-area uses different action spec.
Description: The requested action can not be executed because the board in the work-area requires a different action spec from the one specified.
Solution: Abort the current board and retry the operation, or finish the production of the board in the work-area before starting a new action spec.