Vision Type 72 HEMT (Supplied at 0 degrees) and Vision Type 73 HEMT (Supplied at 45 degrees) For Fuji NXT

Vision Type 72 HEMT (Supplied at 0 degrees) and Vision Type 73 HEMT (Supplied at 45 degrees) For Fuji NXT

It is necessary to enter the body size and element information in part data.

The reference point for the part is the part center.

If the tip of a lead is not square by design then this information must be set in part data so that it is not detected as a defect.

Note that polarity inspection cannot be performed.