Precision and smooth operation of the X-axis is essential for maintaining the machines placing and operating accuracy. The X-axis setup procedure is essential in the following situations:
The motor is exchanged.
The speed down point sensor or speed down point sensor dog position is altered.
The timing belt is removed, comes loose or breaks.
Damage has occurred.
Required Tools:
1 PC – Metric Allen Wrench Set
1 PC – Metal Scale
1 PC – 8 mm Spanner
Tension Meter
Required Jigs:
Device alignment jig (MFU) Z5117ABHPJ2040
Proper data measurement (Jig plate) AJPJ0062
X0, Y0 Dummy nozzle Z5117ABHPJ2050
Nozzle center calibration (Camera 4, 6, 7) ABHPJ6312
Placing accuracy checking jig – glass component (Camera 2) 8342VBDZ0140
Placing accuracy checking jig – glass component (Camera 3) 8342VBDZ0170
Placing accuracy checking jig – glass component (Camera 4) 8342VBDZ0040
Placing accuracy checking jig – glass board (Camera 2, 3) 8342VBDZ0200
Placing accuracy checking jig – glass board (Camera 4) 8342VBDZ0081
Placing accuracy checking jig – Indexing type (Camera 2, 3, 4) ABHPJ6120
Placing accuracy checking jig – Single nozzle type (Camera 2, 3, 4) ABHPJ6110
D0_X, Y calibration jig (MTU) ABHPJ0520
X-axis Resolution: 0.0025 mm / Pulse