P_pattern 5 And 6 Of P Pattern Details On FUJI NXT Scalable Placement Platform

P pattern 5 And 6 Of P Pattern Details On FUJI NXT Scalable Placement Platform

The leads point towards the inside of the body of the part (opposite from types 3 and 4) and are attached to the body at the base of the lead. Due to this, the base cannot be checked with a caliper. The lead tips and widths are checked and the results are used to determine the part positioning.

Type 5: The lead appears black and the outside circumference is white.

Type 6: The lead appears white and the outside circumference is black.

These are primarily used for parts with leads on one side or two opposing sides.

With parts that have leads on two perpendicular sides or more, the lead width direction is only required for determining the positioning, therefore it is recommended to select a different p pattern (type: 11, 12, 15, 16) that matches the processing conditions.

Example Target Parts

Type 5: PLCC socket parts processed with backlighting.

Type 6: Parts with leads pointing towards inside of the body and has a black background and body and is processed with frontlighting.