Having issues with Error Code: 202, 203, 204, 205, 206 on KNS Philips Assembleon ACM SMT Machine? Read our step-by-step SMT maintenance solution below. If you require replacement feeders, nozzles, or sensors, contact SMTBOX for OEM-compatible parts.
Error Code: 202
Error Text: Fail to start transport for error recovery.
Description: An attempt to start the transport during an error recovery action failed.
Cause: No servo power present.
Solution: Switch on servo power.
Error Code: 203
Error Text: Unknown warning
Description: The warning is not specified yet.
Solution: Report error to your service representative.
Error Code: 204
Error Text: Unknown error reported by the system The error is not defined yet.
Cause: An error was detected which is unknown to the human interface.
Solution: Retry and continue and report error to your service representative.
Error Code: 205
Error Text: Unknown warning
Description: The warning is not defined yet.
Cause: A warning was detected which is unknown to the human interface.
Solution: Retry and continue and report warning to your service representative.
Error Code: 206
Error Text: Undefined process error
Description: The process error is not defined yet.
Solution: Retry and continue and report error to your service representative.