Error Code: 202, 203, 204, 205, 206 on KNS Philips Assembleon ACM SMT Machine

KNS Assembleon TTF Twin Tpae Feeder R1.2

Error Code: 202

Error Text: Fail to start transport for error recovery.

Description: An attempt to start the transport during an error recovery action failed.

Cause: No servo power present.

Solution: Switch on servo power.

Error Code: 203

Error Text: Unknown warning

Description: The warning is not specified yet.

Solution: Report error to your service representative.

Error Code: 204

Error Text: Unknown error reported by the system The error is not defined yet.

Cause: An error was detected which is unknown to the human interface.

Solution: Retry and continue and report error to your service representative.

Error Code: 205

Error Text: Unknown warning

Description: The warning is not defined yet.

Cause: A warning was detected which is unknown to the human interface.

Solution: Retry and continue and report warning to your service representative.

Error Code: 206

Error Text: Undefined process error

Description: The process error is not defined yet.

Solution: Retry and continue and report error to your service representative.