Alarm Display: A880. Alarm Name: Fully-closed Serial Encoder Data Alarm on Sony SI-F209 Electronic Part Mounter

Alarm Display: A880.

Alarm Name: Fully-closed Serial Encoder Data Alarm.

1. Situation at Alarm Occurrence: Occurred when the control power supply was turned ON.

Cause: A serial converter unit malfunctioned.
Corrective Actions: Turn the SERVOPACK and serial converter unit power supplies OFF and then ON again. If this alarm occurs frequently replace the serial converter unit.

Cause: A SERVOPACK fault occurred.
Corrective Actions: Replace the SERVOPACK.

2. Situation at Alarm Occurrence: Occurred during operation

Cause: A serial converter unit malfunctioned.
Corrective Actions: Turn the SERVOPACK and serial converter unit power supplies OFF and then ON again. If this alarm occurs frequently replace the serial converter unit.

Cause: A serial converter unit fault occurred.
Corrective Actions: Replace the serial converter unit.

Cause: A SERVOPACK fault occurred.
Corrective Actions: Replace the SERVOPACK.