Having issues with Alarm Display: A.870. Alarm Name: Fully-closed Serial Encoder Checksum Alarm on Sony SI-F209 Electronic Part Mounter? Read our step-by-step SMT maintenance solution below. If you require replacement feeders, nozzles, or sensors, contact SMTBOX for OEM-compatible parts.
Alarm Display: A.870
Alarm Name: Fully-closed Serial Encoder Checksum Alarm
1. Situation at Alarm Occurrence: Occurred when the control power supply was turned ON or during operation.
Cause: A serial converter unit fault occurred and was detected by self-diagnosis of serial converter unit.
Corrective Actions: Set up the serial converter unit. If this alarm occurs frequently replace the senate converter unit.
Cause: A SERVOPACK fault occurred
Corrective Actions: Replace the SERVOPACK
2. Situation at Alarm Occurrence: Occurred when Sensor ON (SENS ON) command was issued
Cause: A serial converter unit fault occurred and was detected by self-diagnosis of serial converter unit.
Corrective Actions: Set up the serial converter unit. If this alarm occurs frequently replace the senate converter unit.