Alarm Display: A. 320. Alarm Name: Regenerative Overload on Sony SI-F209

Sony Si F209 Si E2000 Smd Smt Pick Up Nozzle CF20150 Side C

Alarm Display: A. 320.

Alarm Name: Regenerative Overload.

1. Situation at Alarm Occurrence: Occurred when the control power supply was turned ON.

Cause: A SERVOPACK board fault occurred.
Corrective Actions: Replace the SERVOPACK.

2. Situation at Alarm Occurrence: Occurred when the main circuit power supply was turned ON.

Cause: The power supply voltage is 270 V or more.
Corrective Actions: Correct the input voltage.

3. Situation at Alarm Occurrence: Occurred during normal operation (large increase of regenerative resistor temperature).

Cause: The regenerative energy is excessive, and the regenerating state continued.
Corrective Actions: Select a proper regenerative resistance capacity, or reconsider the load and operation conditions.

4. Situation at Alarm Occurrence: Occurred during normal operation (small increase of regenerative resistor temperature).

Cause: The setting of parameter Pn600 is smaller than the external regenerative resistor’s capacity.
Corrective Actions: Correct the set value of parameter Pn600.

Cause: A SERVOPACK fault occurred.
Corrective Actions: Replace the SERVOPACK.

5. Situation at Alarm Occurrence:

Cause: The regenerative energy is excessive.
Corrective Actions: Select a proper regenerative resistance capacity, or reconsider the load and operation conditions.

SMTBOX Assistant