Enter the body size and element information in part data.
Due to the use of frontlighting, there are cases where the acquired image may vary depending on the shape of the leads and the lighting conditions.
In such cases, it may be necessary to make adjustments to the position, length and width of the lead information in element information. Vision types 123, 124 use the body center while vision types 128, 129 use the part center.