SMTBOX – THT / SMT Machines Feeders, Nozzles and Spare Parts Supplier

Alarm Display: A.830. Alarm Name: Absolute Encoder Battery Error on Sony SI-F209 Electronic Part Mounter

Alarm Display: A.830

Alarm Name: Absolute Encoder Battery Error

1. Situation at Alarm Occurrence: When the control power supply was turned ON. (Setting:Pn002.2=1)

Cause: When the absolute encoder was used as an incremental, a SERVOPACK board fault occurred.
Corrective Actions: Replace the SERVOPACK.

2. Situation at Alarm Occurrence: When the control power supply was turned ON using an absolute encoder. (Setting:Pn002.2=0)

Cause: The battery connection is incorrect.
Corrective Actions: Reconnect the battery.

Cause: The battery voltage is lower than the specified value 2.7 V.
Corrective Actions: Replace the battery, and then turn on the power to the encoder.

Cause: A SERVOPACK board fault occurred.
Corrective Actions: Replace the SERVOPACK.

Exit mobile version